← Manuals
EN TR DE

SC-16 SmartControl

The channel is locked. Your voice is the key.
Smart gain-sharing automixer · 16 / 8 / 4 / 2 channels · VST3 · AU · Standalone

SC-16 SmartControl is a smart gain-sharing automixer for live speech: Dugan-style share mathematics in up to four independent groups, speech-probability weighting (AI VAD), dynamic plosive control, and FLOORLOCK™ — a voice-keyed channel lock. The audio path is zero samples long: every detector runs in a side chain, so SC-16 adds no latency and no phase penalty. One rule drives the whole design: total system gain never rises with the number of open microphones (ΣG ≤ 1 per group) — feedback margin is engineered, not hoped for.

SC-16 interface
SC-16 face. The numbers below refer to this view.

Top panel

1
MANUALOpens this manual.
2
SHARE MONITORPer-channel share history, 0 to −40 dB. Line color = share group; brightness follows speech probability. Header: NOM (microphones currently holding real share), ΣG (largest per-group share sum — stays ≤ 1.00 by design), and the channel count. “share monitor idle” means the host is not sending audio.
3
OUTPUTMaster trim after the automix, ±12 dB. Double-click any value on the face to type an exact number; Shift-drag is fine adjustment; double-click a knob returns its default.
4
ONProcessing engaged. Pressing it while BYPASS is lit re-engages processing.
5
BYPASSFull bypass — audio passes untouched.
6
LINK · SLOTJoins this instance to the family link bus (RP-1 rack). SLOT shows the assigned position (01–16); “—” means the link is off.

AUTOMIX

7
DEPTHHow far below the active talker an idle channel’s share sits (−40…−6 dB, default −20 dB). Deeper = drier and more clinical; −20 dB keeps the room natural, and the last mic stays on for free.
8
ATTACKHow fast a channel rises to its earned share (0.5–20 ms, default 2 ms).
9
RELEASEHow fast a share falls back after speech (20–500 ms, default 90 ms).
10
SC HPFHigh-pass on the detector side chain only (40–400 Hz, default 120 Hz). Rumble, footsteps and stage LF stop earning share; the audio path is untouched.

AI VAD

11
VADVoice-activity detection on/off. Runs on a 16 kHz side chain — zero added latency. The active engine is named in the status block (22).
12
WEIGHTFeeds speech probability into the share math. It is a weight, not a lock: the channel opens on level in ~2 ms, and within ~10 ms the VAD pulls back whatever is not speech — coughs, spill, applause.
13
SENSDecision threshold (0.20–0.90, default 0.55). Lower = accepts softer, less certain speech.
14
HANGHow long speech evidence is held across word gaps (50–600 ms, default 180 ms).
15
REJECTThe share weight non-speech may keep (0.00–0.40, default 0.05). 0 = full rejection.

DE-PLOSIVE

16
DPDynamic plosive control on/off. A dynamic low shelf that engages only while a plosive thump (30–90 Hz) is actually happening. No fixed high-pass — the body of the voice is never thinned.
17
THRESHPlosive sensitivity (−12…+18 dB, default 0 dB): how much low-band overshoot against the 100–500 Hz reference counts as a plosive. Raise it if a very low voice triggers cuts on sustained notes.
18
DEPTHMaximum shelf cut during a plosive (−24…0 dB, default −15 dB).
19
SHELFShelf corner frequency (60–160 Hz, default 100 Hz).
20
ATKEngage speed (0.5–5 ms, default 1.5 ms).
21
RELRecovery speed (10–80 ms, default 30 ms).
22
STATUSChannel mode (16/8/4/2 CH, taken from the host bus), the active VAD engine, and the latency line: 0 SMP — the audio path is zero samples; all detection is side-chain.

FLOORLOCK™ · VOICE KEY

23
LOCKFLOORLOCK on/off. Off: the channel behaves as a plain automixer input.
24
MARGINHow far above the tracked room floor the signal must rise to unlock (+6…+15 dB, default +9 dB). The floor is measured continuously (28), so the threshold rides the room: when the crowd gets louder, the threshold climbs with it.
25
RANGEAttenuation while LOCKED (−60…−6 dB, default −20 dB). Fully counter-clockwise reads FULL — an exact mute. −12…−20 dB is the natural-sounding zone on stage.
26
ATTACK · HOLD · RELEASEUnlock speed (0.5–20 ms), minimum open time (50–500 ms) and re-lock speed (30–500 ms). With VOICE KEY active, staying open is decided by the sound itself — ongoing speech evidence; HOLD only sets the shortest stay.
27
VOICE KEYHow much speech evidence unlocking requires. OFF — level alone, exact v1 behavior, for rigs tuned before v2. STRICT — the channel stays attenuated until speech is proven; costs a touch of the first onset, made for loud stages. NORMAL — level opens, ~50 ms of evidence confirms; anything that fails the proof is re-locked at once (default). FAST — quickest opening, loosest proof, for quiet rooms and podium work.
28
THRESHOLD · FLOORLive telemetry for channel 1: the tracked room floor and the resulting unlock threshold (floor + MARGIN). “—” = lock off. These are the same numbers the RP-1 telemetry log carries — the face and the log cannot disagree.
29
EVIDENCE · STATEWhy the channel is open, not just that it is. VOICED — larynx harmonics detected. SIBILANT — s/sh/f energy. CHECKING (amber) — the signal passed the level test but has not yet proven speech; the state reads ATTENUATED. Green LED + UNLOCKED = open; LOCKED = closed; LOCK OFF = FLOORLOCK disabled.

Channel strips (01–16)

30
CHANNEL · PRESENCEChannel number and presence LED: lit in the group color while the channel holds real share (bright = talking, dim = partial).
31
METERSLeft — LVL: input level (−60…0 dB). Middle — SHARE: the earned share (−40…0 dB) in the group color; brightness follows speech probability. Right — DP GR: de-plosive gain reduction (0…−18 dB, drawn top-down).
32
SHARE READOUTThe channel’s current share in dB. “–∞” = fully closed; “–” = no audio running.
33
WEIGHTChairman priority, ±12 dB: biases this channel’s earned share against the others without touching its input gain.
34
GRP · B · MGRP cycles the share group — four colors, four independent pools (e.g. podium / panel / audience); ΣG = 1 holds per group. B = bypass: unity gain, outside the share pool (program and playback feeds). M = mute: closed and outside the pool.

Noise reference

35
NSThe “17th channel”. Set LEVEL to the room’s crowd/HVAC reference. The bar shows the loudest microphone against the reference line; while no mic beats it, the strip flags DUCK — the mixer knows nobody is talking, and ambient noise cannot hold channels open. NS ON arms it.

Quick start

  1. Gain-stage honestly at the console. SC-16 expects real levels, not hot inputs.
  2. Assign groups (34): one pool per stage zone — podium, panel, audience.
  3. AUTOMIX: leave DEPTH at −20 dB, ATTACK 2 ms, RELEASE 90 ms. Watch ΣG stay ≤ 1.00 on the share monitor (2).
  4. Switch VAD and WEIGHT on. SENS 0.55; move toward 0.70 on noisy stages.
  5. FLOORLOCK: LOCK on, VOICE KEY NORMAL, MARGIN +9 dB, RANGE −20 dB. Watch 28/29 through a minute of real program; if non-speech still blips through, step VOICE KEY to STRICT.
PDF versions of this manual:
EN PDF TR PDF DE PDF
SC-16 SmartControl · FLOORLOCK™ / VOICE KEY — “Opens for speech. Nothing else.” · © 2026 Yilmaz Yeniyol. All rights reserved.